User Probes and Arbitrary Parameter Sweeps in Victory Device

sim std sept 2022One of the new features in Victory Device is the ability to add user managed parameters to a log file. This can be used when sweeping parameters (manually or in a Deckbuild loop), such as doping, stress, or layer thicknesses, to add the swept parameter to a log file. To do so, simply create a USER probe (with an optional name), and set the parameter USER on the MODELS statement to some value. This parameter (and value) will be added to the log file. The available user parameters are USER1, USER2, USER3, and USER4. The following shows a DeckBuild loop (go victoryd) to simulate the effect of varying STRESS_XX on the mobility.