{"id":31554,"date":"1999-04-01T16:58:15","date_gmt":"1999-04-01T16:58:15","guid":{"rendered":"https:\/\/silvaco.com\/%eb%b6%84%eb%a5%98%eb%90%98%ec%a7%80-%ec%95%8a%ec%9d%8c\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/"},"modified":"2026-10-15T14:41:46","modified_gmt":"2026-10-15T21:41:46","slug":"intrinsic-capacitance-parameter-extraction-in-utmost-iii","status":"publish","type":"post","link":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/","title":{"rendered":"Intrinsic Capacitance Parameter Extraction in UTMOST III"},"content":{"rendered":"<h1>Intrinsic Capacitance Parameter Extraction in <i>UTMOST III<\/i><\/h1>\n<h3 class=\"feature\" align=\"left\">Introduction<\/h3>\n<p class=\"regular\" align=\"left\">The intrinsic capacitance parameter extraction routine (INTCAP) is in the CAP analysis section of the\u00a0<b><i>UTMOST III<\/i><\/b>\u00a0MOS module (Routine#67). The INTCAP routine has 5 different intrinsic cap measurements and a &#8220;simulation only&#8221; capability for all intrinsic caps. Recent developments have improved the INTCAP routine. Users should have\u00a0<b><i>UTMOST III<\/i><\/b>\u00a0MOS module version 15.2.0 or higher to be able use the examples and explanations presented in this article. The INTCAP routine allows users to measure the MOS capacitances when the device is under DC bias and conducting current.<\/p>\n<p><img loading=\"lazy\" width=\"1288\" height=\"1669\" src=\"https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1.jpg\" class=\"cleaned-enfold-image\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1.jpg 1288w, https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1-232x300.jpg 232w, https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1-795x1030.jpg 795w, https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1-768x995.jpg 768w, https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1-1185x1536.jpg 1185w, https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1-1158x1500.jpg 1158w, https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1-544x705.jpg 544w, https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1-29x37.jpg 29w, https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1-42x55.jpg 42w, https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1-37x48.jpg 37w\" sizes=\"auto, (max-width: 1288px) 100vw, 1288px\" \/><\/p>\n<p><a href=\"https:\/\/silvaco.com\/dynamicweb\/jsp\/downloads\/DownloadDocStepsAction.do?req=download&#038;nm=simstd_apr_1999_a1.pdf\" class=\"BGT-btn\" target=\"_blank\" rel=\"noopener noreferrer\">Download Simulation Standard<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The intrinsic capacitance parameter extraction routine (INTCAP) is in the CAP analysis section of the\u00a0UTMOST III\u00a0MOS module (Routine#67). The INTCAP routine has 5 different intrinsic cap measurements and a &#8220;simulation only&#8221; capability for all intrinsic caps. Recent developments have improved the INTCAP routine. Users should have\u00a0UTMOST III\u00a0MOS module version 15.2.0 or higher to be able use the examples and explanations presented in this article. The INTCAP routine allows users to measure the MOS capacitances when the device is under DC bias and conducting current.<\/p>\n","protected":false},"author":12,"featured_media":21504,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"categories":[7486],"tags":[],"class_list":["post-31554","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-simulation-standard-ko","entry","has-media"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.7 (Yoast SEO v28.7) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Intrinsic Capacitance Parameter Extraction in UTMOST III - Silvaco<\/title>\n<meta name=\"description\" content=\"The intrinsic capacitance parameter extraction routine (INTCAP) is in the CAP analysis section of the\u00a0UTMOST III\u00a0MOS module\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/\" \/>\n<meta property=\"og:locale\" content=\"ko_KR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Intrinsic Capacitance Parameter Extraction in UTMOST III\" \/>\n<meta property=\"og:description\" content=\"The intrinsic capacitance parameter extraction routine (INTCAP) is in the CAP analysis section of the\u00a0UTMOST III\u00a0MOS module\" \/>\n<meta property=\"og:url\" content=\"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/\" \/>\n<meta property=\"og:site_name\" content=\"Silvaco\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/SilvacoSoftware\/\" \/>\n<meta property=\"article:published_time\" content=\"1999-04-01T16:58:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-15T21:41:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1288\" \/>\n\t<meta property=\"og:image:height\" content=\"1669\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Casey Molver\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@SilvacoSoftware\" \/>\n<meta name=\"twitter:site\" content=\"@SilvacoSoftware\" \/>\n<meta name=\"twitter:label1\" content=\"\uae00\uc4f4\uc774\" \/>\n\t<meta name=\"twitter:data1\" content=\"Casey Molver\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/silvaco.com\\\/ko\\\/simulation-standard-ko\\\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/silvaco.com\\\/ko\\\/simulation-standard-ko\\\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\\\/\"},\"author\":{\"name\":\"Casey Molver\",\"@id\":\"https:\\\/\\\/silvaco.com\\\/ja\\\/#\\\/schema\\\/person\\\/2763eb741ca5ac04477fdff50ed84c80\"},\"headline\":\"Intrinsic Capacitance Parameter Extraction in UTMOST III\",\"datePublished\":\"1999-04-01T16:58:15+00:00\",\"dateModified\":\"2026-10-15T21:41:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/silvaco.com\\\/ko\\\/simulation-standard-ko\\\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\\\/\"},\"wordCount\":104,\"image\":{\"@id\":\"https:\\\/\\\/silvaco.com\\\/ko\\\/simulation-standard-ko\\\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/silvaco.com\\\/wp-content\\\/uploads\\\/simulationstandard\\\/simstd_apr_1999_a1.jpg\",\"articleSection\":[\"Simulation Standard\"],\"inLanguage\":\"ko-KR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/silvaco.com\\\/ko\\\/simulation-standard-ko\\\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\\\/\",\"url\":\"https:\\\/\\\/silvaco.com\\\/ko\\\/simulation-standard-ko\\\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\\\/\",\"name\":\"Intrinsic Capacitance Parameter Extraction in UTMOST III - Silvaco\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/silvaco.com\\\/ja\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/silvaco.com\\\/ko\\\/simulation-standard-ko\\\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/silvaco.com\\\/ko\\\/simulation-standard-ko\\\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/silvaco.com\\\/wp-content\\\/uploads\\\/simulationstandard\\\/simstd_apr_1999_a1.jpg\",\"datePublished\":\"1999-04-01T16:58:15+00:00\",\"dateModified\":\"2026-10-15T21:41:46+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/silvaco.com\\\/ja\\\/#\\\/schema\\\/person\\\/2763eb741ca5ac04477fdff50ed84c80\"},\"description\":\"The intrinsic capacitance parameter extraction routine (INTCAP) is in the CAP analysis section of the\u00a0UTMOST III\u00a0MOS module\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/silvaco.com\\\/ko\\\/simulation-standard-ko\\\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\\\/#breadcrumb\"},\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/silvaco.com\\\/ko\\\/simulation-standard-ko\\\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/silvaco.com\\\/ko\\\/simulation-standard-ko\\\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\\\/#primaryimage\",\"url\":\"https:\\\/\\\/silvaco.com\\\/wp-content\\\/uploads\\\/simulationstandard\\\/simstd_apr_1999_a1.jpg\",\"contentUrl\":\"https:\\\/\\\/silvaco.com\\\/wp-content\\\/uploads\\\/simulationstandard\\\/simstd_apr_1999_a1.jpg\",\"width\":1288,\"height\":1669},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/silvaco.com\\\/ko\\\/simulation-standard-ko\\\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/silvaco.com\\\/zh-hans\\\/%e9%a6%96%e9%a1%b5\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Intrinsic Capacitance Parameter Extraction in UTMOST III\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/silvaco.com\\\/ja\\\/#website\",\"url\":\"https:\\\/\\\/silvaco.com\\\/ja\\\/\",\"name\":\"Silvaco\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/silvaco.com\\\/ja\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ko-KR\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/silvaco.com\\\/ja\\\/#\\\/schema\\\/person\\\/2763eb741ca5ac04477fdff50ed84c80\",\"name\":\"Casey Molver\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/3dba2e48e0c4a977ea23fa75d38750a7763843df78307070478340a2517b8d6b?s=96&d=blank&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/3dba2e48e0c4a977ea23fa75d38750a7763843df78307070478340a2517b8d6b?s=96&d=blank&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/3dba2e48e0c4a977ea23fa75d38750a7763843df78307070478340a2517b8d6b?s=96&d=blank&r=g\",\"caption\":\"Casey Molver\"},\"url\":\"https:\\\/\\\/silvaco.com\\\/ko\\\/author\\\/caseym\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Intrinsic Capacitance Parameter Extraction in UTMOST III - Silvaco","description":"The intrinsic capacitance parameter extraction routine (INTCAP) is in the CAP analysis section of the\u00a0UTMOST III\u00a0MOS module","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/","og_locale":"ko_KR","og_type":"article","og_title":"Intrinsic Capacitance Parameter Extraction in UTMOST III","og_description":"The intrinsic capacitance parameter extraction routine (INTCAP) is in the CAP analysis section of the\u00a0UTMOST III\u00a0MOS module","og_url":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/","og_site_name":"Silvaco","article_publisher":"https:\/\/www.facebook.com\/SilvacoSoftware\/","article_published_time":"1999-04-01T16:58:15+00:00","article_modified_time":"2026-10-15T21:41:46+00:00","og_image":[{"width":1288,"height":1669,"url":"https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1.jpg","type":"image\/jpeg"}],"author":"Casey Molver","twitter_card":"summary_large_image","twitter_creator":"@SilvacoSoftware","twitter_site":"@SilvacoSoftware","twitter_misc":{"\uae00\uc4f4\uc774":"Casey Molver"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/#article","isPartOf":{"@id":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/"},"author":{"name":"Casey Molver","@id":"https:\/\/silvaco.com\/ja\/#\/schema\/person\/2763eb741ca5ac04477fdff50ed84c80"},"headline":"Intrinsic Capacitance Parameter Extraction in UTMOST III","datePublished":"1999-04-01T16:58:15+00:00","dateModified":"2026-10-15T21:41:46+00:00","mainEntityOfPage":{"@id":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/"},"wordCount":104,"image":{"@id":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/#primaryimage"},"thumbnailUrl":"https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1.jpg","articleSection":["Simulation Standard"],"inLanguage":"ko-KR"},{"@type":"WebPage","@id":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/","url":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/","name":"Intrinsic Capacitance Parameter Extraction in UTMOST III - Silvaco","isPartOf":{"@id":"https:\/\/silvaco.com\/ja\/#website"},"primaryImageOfPage":{"@id":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/#primaryimage"},"image":{"@id":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/#primaryimage"},"thumbnailUrl":"https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1.jpg","datePublished":"1999-04-01T16:58:15+00:00","dateModified":"2026-10-15T21:41:46+00:00","author":{"@id":"https:\/\/silvaco.com\/ja\/#\/schema\/person\/2763eb741ca5ac04477fdff50ed84c80"},"description":"The intrinsic capacitance parameter extraction routine (INTCAP) is in the CAP analysis section of the\u00a0UTMOST III\u00a0MOS module","breadcrumb":{"@id":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/#breadcrumb"},"inLanguage":"ko-KR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/"]}]},{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/#primaryimage","url":"https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1.jpg","contentUrl":"https:\/\/silvaco.com\/wp-content\/uploads\/simulationstandard\/simstd_apr_1999_a1.jpg","width":1288,"height":1669},{"@type":"BreadcrumbList","@id":"https:\/\/silvaco.com\/ko\/simulation-standard-ko\/intrinsic-capacitance-parameter-extraction-in-utmost-iii\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/silvaco.com\/zh-hans\/%e9%a6%96%e9%a1%b5\/"},{"@type":"ListItem","position":2,"name":"Intrinsic Capacitance Parameter Extraction in UTMOST III"}]},{"@type":"WebSite","@id":"https:\/\/silvaco.com\/ja\/#website","url":"https:\/\/silvaco.com\/ja\/","name":"Silvaco","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/silvaco.com\/ja\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ko-KR"},{"@type":"Person","@id":"https:\/\/silvaco.com\/ja\/#\/schema\/person\/2763eb741ca5ac04477fdff50ed84c80","name":"Casey Molver","image":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/secure.gravatar.com\/avatar\/3dba2e48e0c4a977ea23fa75d38750a7763843df78307070478340a2517b8d6b?s=96&d=blank&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/3dba2e48e0c4a977ea23fa75d38750a7763843df78307070478340a2517b8d6b?s=96&d=blank&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/3dba2e48e0c4a977ea23fa75d38750a7763843df78307070478340a2517b8d6b?s=96&d=blank&r=g","caption":"Casey Molver"},"url":"https:\/\/silvaco.com\/ko\/author\/caseym\/"}]}},"_links":{"self":[{"href":"https:\/\/silvaco.com\/ko\/wp-json\/wp\/v2\/posts\/31554","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/silvaco.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/silvaco.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/silvaco.com\/ko\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/silvaco.com\/ko\/wp-json\/wp\/v2\/comments?post=31554"}],"version-history":[{"count":2,"href":"https:\/\/silvaco.com\/ko\/wp-json\/wp\/v2\/posts\/31554\/revisions"}],"predecessor-version":[{"id":956279,"href":"https:\/\/silvaco.com\/ko\/wp-json\/wp\/v2\/posts\/31554\/revisions\/956279"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/silvaco.com\/ko\/wp-json\/wp\/v2\/media\/21504"}],"wp:attachment":[{"href":"https:\/\/silvaco.com\/ko\/wp-json\/wp\/v2\/media?parent=31554"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/silvaco.com\/ko\/wp-json\/wp\/v2\/categories?post=31554"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/silvaco.com\/ko\/wp-json\/wp\/v2\/tags?post=31554"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}